<doi_batch xmlns="http://www.crossref.org/schema/4.4.0" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" version="4.4.0"><head><doi_batch_id>008d4ffb-4ee2-4e79-987f-fd7cb1d4d56d</doi_batch_id><timestamp>20210115110059177</timestamp><depositor><depositor_name>wsea</depositor_name><email_address>mdt@crossref.org</email_address></depositor><registrant>MDT Deposit</registrant></head><body><journal><journal_metadata language="en"><full_title>WSEAS TRANSACTIONS ON POWER SYSTEMS</full_title><issn media_type="print">1790-5060</issn><doi_data><doi>10.37394/232016</doi><resource>http://wseas.org/wseas/cms.action?id=4057</resource></doi_data></journal_metadata><journal_issue><publication_date media_type="online"><month>2</month><day>17</day><year>2020</year></publication_date><publication_date media_type="print"><month>2</month><day>17</day><year>2020</year></publication_date><journal_volume><volume>15</volume><doi_data><doi>10.37394/232016.2020.15</doi><resource>http://wseas.org/wseas/cms.action?id=23192</resource></doi_data></journal_volume></journal_issue><journal_article language="en"><titles><title>Frequency Security Constrained Energy Management in an Isolated Power System</title></titles><contributors><person_name sequence="first" contributor_role="author"><given_name>Umer</given_name><surname>Akram</surname><affiliation>School of IT and Electrical Engineering, The University of Queensland, Australia</affiliation></person_name><person_name sequence="additional" contributor_role="author"><given_name>Mithulananthan</given_name><surname>Nadarajah</surname><affiliation>School of IT and Electrical Engineering, The University of Queensland, Australia</affiliation></person_name><person_name sequence="additional" contributor_role="author"><given_name>Rakibuzzaman</given_name><surname>Shah</surname><affiliation>School of Science Engineering and Information Technology, Federation University, Australia</affiliation></person_name><person_name sequence="additional" contributor_role="author"><given_name>Saifullah</given_name><surname>Shafiq</surname><affiliation>Electrical Engineering Department, Prince Mohammad Bin Fahd University, Saudi Arabia</affiliation></person_name></contributors><jats:abstract xmlns:jats="http://www.ncbi.nlm.nih.gov/JATS1"><jats:p>Short-term frequency instability is one of the major challenges that arise due to large-scale penetration of converter interfaced renewable energy sources (RESs) in isolated power systems. The short-term frequency instability is associated with high values of rate of change of frequency (RoCoF) and larger frequency excursions. In this paper, a frequency constrained energy management algorithm is proposed. The proposed algorithm manages the power output of RESs, energy storage system, and electric vehicles (EVs) in such a way that the system keeps nonsynchronous power reserve for providing virtual inertia support to avoid high values of RoCoF and frequency excursions. The non-synchronous power reserve is readily available and when deployed can limit the RoCoF as per the required standard. The proposed management algorithm selects the non-synchronous power reserve from different resources, i.e., RES (solar PV, wind turbine), energy storage, and EV, depending on the availability and system loading conditions. Simulation results show the effectiveness of the proposed algorithm.</jats:p></jats:abstract><publication_date media_type="online"><month>12</month><day>8</day><year>2020</year></publication_date><publication_date media_type="print"><month>12</month><day>8</day><year>2020</year></publication_date><pages><first_page>222</first_page><last_page>229</last_page></pages><ai:program xmlns:ai="http://www.crossref.org/AccessIndicators.xsd" name="AccessIndicators"><ai:free_to_read start_date="2020-12-08"/><ai:license_ref applies_to="am" start_date="2020-12-08">https://www.wseas.org/multimedia/journals/power/2020/a525116-068.pdf</ai:license_ref></ai:program><archive_locations><archive name="Portico"/></archive_locations><doi_data><doi>10.37394/232016.2020.15.26</doi><resource>https://www.wseas.org/multimedia/journals/power/2020/a525116-068.pdf</resource></doi_data><citation_list><citation key="ref0"><doi>10.1016/j.rser.2019.109626</doi><unstructured_citation>U.  Akram,  M.  Nadarajah,  R.  Shah,  and  F. Milano, “A review on rapid responsive energy storage  technologies  for  frequency  regulation in  modern  power  systems,” Renewable  and Sustainable   Energy   Reviews,  vol.  120,  p. 109626, 2020.</unstructured_citation></citation><citation key="ref1"><doi>10.1109/access.2020.3003369</doi><unstructured_citation>S. Shafiq, U. B. Irshad, M. Al-Muhaini, S. Z. Djokic, and U. Akram, “Reliability evaluation of  composite  power  systems:  Evaluating  the impact  of  full  and  plug-in  hybrid  electric vehicles,” IEEE Access, pp. 114 305–114 314, 2020. </unstructured_citation></citation><citation key="ref2"><doi>10.1049/iet-rpg.2017.0010</doi><unstructured_citation>U. Akram, M. Khalid, and S. Shafiq, “Optimal sizing  of  a  wind/solar/battery  hybrid  grid-connected  microgrid  system,” IET  Renewable Power  Generation, vol. 12, no. 1, pp. 72–80, 2017. </unstructured_citation></citation><citation key="ref3"><doi>10.1109/tpwrs.2004.825981</doi><unstructured_citation>P.  Kundur,  J.  Paserba,  V.  Ajjarapu,  G. Andersson,  A.  Bose,  C.  Canizares,  N. Hatziargyriou, D. Hill, A. Stankovic, C. Taylor et  al., “ Definition and classification of power system  stability  IEEE/CIGRE  joint  task  force on    stability  terms  and  definitions,” IEEE Transactions on Power Systems, vol. 19, no. 3, pp. 1387–1401, 2004.</unstructured_citation></citation><citation key="ref4"><unstructured_citation>AEMO,  “Fast  frequency  response  in  the NEM,” Future power system security program, AEMO   Information   &amp;   Support   Hub,   Tech. Rep., Australia, 2017.</unstructured_citation></citation><citation key="ref5"><unstructured_citation>CIGRE working group B4.62, “Connection of wind farms to weak AC networks,” 2016.</unstructured_citation></citation><citation key="ref6"><doi>10.1016/j.rser.2016.11.170</doi><unstructured_citation>M.  Dreidy,  H.  Mokhlis,  and  S.  Mekhilef, “Inertia  response  and  frequency  control techniques  for renewable  energy  sources:  A review,” Renewable  and  Sustainable  Energy Reviews, vol. 69, pp. 144–155, 2017.</unstructured_citation></citation><citation key="ref7"><doi>10.1109/tpwrs.2008.920076</doi><unstructured_citation>N.  R.  Ullah,  T.  Thiringer,  and  D.  Karlsson, “Temporary primary frequency control support by variable speed wind turbines potential and applications,” IEEE   Transactions   on   Power Systems, vol. 23, no. 2, pp. 601-612, 2008.</unstructured_citation></citation><citation key="ref8"><doi>10.1109/tpwrs.2019.2939411</doi><unstructured_citation>R. Azizipanah-Abarghooee, M. Malekpour, T. Dragicevic,  F.  Blaabjerg,  and  V.  Terzija,  “A linear inertial response emulation for variable speed  wind  turbines,” IEEE  Transactions  on Power  Systems, vol. 35, no. 2, pp. 1198-1208, 2019.</unstructured_citation></citation><citation key="ref9"><doi>10.1109/tpwrs.2012.2208233</doi><unstructured_citation>K.  Vidyanandan  and  N.  Senroy,  “Primary frequency   regulation   by   deloaded   wind turbines   using   variable   droop,” IEEE Transactions on Power Systems, vol. 28, no. 2, pp. 837–846, 2012.</unstructured_citation></citation><citation key="ref10"><doi>10.1016/j.ijepes.2014.02.033</doi><unstructured_citation>P.  Zarina,  S.  Mishra,  and  P.  Sekhar, “Exploring  frequency  control  capability  of  a PV  system  in  a  hybrid  PV-rotating  machine-without storage system,” International Journal of Electrical Power &amp; Energy Systems, vol. 60, pp. 258–267, 2014.</unstructured_citation></citation><citation key="ref11"><doi>10.1109/tsg.2010.2045163</doi><unstructured_citation>S. Han, S. Han, and K. Sezaki, “Development of  an  optimal  vehicle-togrid  aggregator  for frequency  regulation,” IEEE  Transactions  on Smart Grid, vol. 1, no. 1, pp. 65–72, 2010.</unstructured_citation></citation><citation key="ref12"><doi>10.1109/tpwrs.2013.2252029</doi><unstructured_citation>H.  Liu,  Z.  Hu,  Y.  Song,  and  J.  Lin, “Decentralized  vehicle-to-grid  control  for primary  frequency  regulation  considering charging  demands,” IEEE   Transactions   on Power Systems, vol. 28, no. 3, pp. 3480–3489, 2013.</unstructured_citation></citation><citation key="ref13"><doi>10.1109/access.2019.2936400</doi><unstructured_citation>S. K. Das, M. Rahman, S. K. Paul, M. Armin, P.  N.  Roy,  and  N.  Paul,  “High-performance robust  controller  design  of  plug-in  hybrid electric  vehicle  for  frequency  regulation  of smart  grid  using  linear  matrix  inequality approach,” IEEE  Access, vol.  7,  pp.  116911–116924, 2019.</unstructured_citation></citation><citation key="ref14"><doi>10.1109/tpwrs.2020.3001997</doi><unstructured_citation>U.  Akram,  M.  Nadarajah,  M.  Q.  RAZA,  R. Shah,  and  F.  Milano,  “Rocof  restrictive planning  framework  and  wind  speed  forecast informed operation strategy of energy storage system,” IEEE     Transactions     on     Power Systems, 2020.</unstructured_citation></citation><citation key="ref15"><doi>10.1109/tpwrs.2015.2503565</doi><unstructured_citation>V.  Knap,  S.  K.  Chaudhary,  D.-I.  Stroe,  M. Swierczynski,   B.-I.   Craciun,   and   R. Teodorescu,  “Sizing  of  an  energy  storage system  for  grid  inertial  response  and  primary frequency  reserve,” IEEE   Transactions   on Power Systems, vol. 31, no. 5, pp. 3447–3456, 2015.</unstructured_citation></citation><citation key="ref16"><doi>10.1049/iet-gtd.2018.7064</doi><unstructured_citation>U.  Akram,  R.  Shah,  and  N.  Mithulananthan, “Hybrid energy stoarage system for frequency regulation in microgrids with source and load uncertainties,” IET  Generation,  Transmission &amp; Distribution, vol. 13, no. 22, pp. 5048–5057, 2019. </unstructured_citation></citation><citation key="ref17"><doi>10.1016/j.est.2017.05.009</doi><unstructured_citation>M.  Elsisi,  M.  Soliman,  M.  Aboelela,  and  W. Mansour, “Optimal design of model predictive control with superconducting magnetic energy storage for load frequency control of nonlinear hydrothermal power system using bat inspired algorithm,” Journal of Energy Storage, vol. 12, pp. 311–318, 2017.</unstructured_citation></citation><citation key="ref18"><doi>10.1016/j.est.2020.101221</doi><unstructured_citation>M.  Babaei,  E.  Azizi,  M. T.  Beheshti,  and  M. Hadian,  “Data–driven  load  management  of stand-alone  residential  buildings  including renewable  resources,  energy  storage  system, and  electric  vehicle,” Journal   of   Energy Storage, vol. 28, p. 101221, 2020.</unstructured_citation></citation></citation_list></journal_article></journal></body></doi_batch>