<doi_batch xmlns="http://www.crossref.org/schema/4.4.0" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" version="4.4.0"><head><doi_batch_id>ded2e988-7ec5-4e7d-be31-7e61712755bb</doi_batch_id><timestamp>20210114131029525</timestamp><depositor><depositor_name>wsea</depositor_name><email_address>mdt@crossref.org</email_address></depositor><registrant>MDT Deposit</registrant></head><body><journal><journal_metadata language="en"><full_title>WSEAS TRANSACTIONS ON POWER SYSTEMS</full_title><issn media_type="print">1790-5060</issn><doi_data><doi>10.37394/232016</doi><resource>http://wseas.org/wseas/cms.action?id=4057</resource></doi_data></journal_metadata><journal_issue><publication_date media_type="online"><month>2</month><day>17</day><year>2020</year></publication_date><publication_date media_type="print"><month>2</month><day>17</day><year>2020</year></publication_date><journal_volume><volume>15</volume><doi_data><doi>10.37394/232016.2020.15</doi><resource>http://wseas.org/wseas/cms.action?id=23192</resource></doi_data></journal_volume></journal_issue><journal_article language="en"><titles><title>Comparative analysis of Maximum Power Point Tracking Algorithms for Photovoltaic Applications</title></titles><contributors><person_name sequence="first" contributor_role="author"><given_name>Bharathi Sankar</given_name><surname>Ammaiyappan</surname><affiliation>School of Electronics Engineering,  VIT University Chennai Campus, Chennai, INDIA</affiliation></person_name><person_name sequence="additional" contributor_role="author"><given_name>R.</given_name><surname>Seyezhai</surname><affiliation>Department of Electrical and Electronics Engineering,  Renewable Energy Conversion Lab, SSN College of Engineering, Chennai, INDIA</affiliation></person_name></contributors><jats:abstract xmlns:jats="http://www.ncbi.nlm.nih.gov/JATS1"><jats:p>Currently, photovoltaic system has gained importance in electrical power generation system, since it is a clean and renewable energy source. An important characteristic of photovoltaic panels is that the available maximum power is provided only in a single operating point called maximum power point. But the position of maximum power point is not fixed and it moves according to the varying irradiance, varying temperature and the load. This requires a mechanism called maximum power point tracking (MPPT) so that maximum power is obtained effectively. In the literature, many classical methods have been developed and implemented to track the maximum power point. The main objective of this paper is to study and analyze the classical techniques such as Perturb and Observe (P&amp;O), Incremental Conductance (IC) and Fuzzy Logic Control (FLC) algorithms and propose an Adaptive Fuzzy Logic Control (AFLC) for MPPT. The performance of AFLC is compared with the conventional MPPT techniques for varying irradiance. The significance of these methods are studied by implementing the algorithm in MATLAB. The experimental results show the effectiveness and feasibility of the proposed method and the results are verified. The results reveal that the adaptive FLC can quickly track change of MPP for various light intensity and delivers higher power compared to the classical algorithms.</jats:p></jats:abstract><publication_date media_type="online"><month>9</month><day>15</day><year>2020</year></publication_date><publication_date media_type="print"><month>9</month><day>15</day><year>2020</year></publication_date><pages><first_page>161</first_page><last_page>171</last_page></pages><ai:program xmlns:ai="http://www.crossref.org/AccessIndicators.xsd" name="AccessIndicators"><ai:free_to_read start_date="2020-09-15"/><ai:license_ref applies_to="am" start_date="2020-09-15">https://www.wseas.org/multimedia/journals/power/2020/a405116-074.pdf</ai:license_ref></ai:program><archive_locations><archive name="Portico"/></archive_locations><doi_data><doi>10.37394/232016.2020.15.20</doi><resource>https://www.wseas.org/multimedia/journals/power/2020/a405116-074.pdf</resource></doi_data><citation_list><citation key="ref0"><doi>10.1109/iapec.2011.5779863</doi><unstructured_citation>Mei Shan Ngan and Chee Wei Tan , A Study  of  Maximum  Power  Point Tracking  Algorithms  for  Stand-alone Photovoltaic  Systems.  IEEE  applied power electronics colloquium, (IAPEC), pp .22-27, (2011).</unstructured_citation></citation><citation key="ref1"><doi>10.1016/j.solmat.2005.10.023</doi><unstructured_citation>Salas,  V,  Olias,  E,  Barrado,  A  and Lazaro,  A.  ,Review  of  the  maximum power  point  tracking  algorithms  for stand-alone photovoltaic systems . Solar Energy Materials &amp; Solar Cells, vol. 90, pp.1555-1578, (2006).</unstructured_citation></citation><citation key="ref2"><doi>10.1109/pvsc.2000.916230</doi><unstructured_citation>Hohm, DP and Ropp, ME. ,Comparative Study  of  Maximum  Power  Point Tracking Algorithms using experimental, programmable, maximum power  point  tracking  test  bed’,  IEEE Photovoltaic  specialist  conference,  pp. 1699-1702, (2000).</unstructured_citation></citation><citation key="ref3"><doi>10.1063/1.4928519</doi><unstructured_citation>Yanhong  Kou,  Yinshui  Xia and  Yidie Ye.  ,  Fast  variable  step-size  maximum power  point  tracking  method  for photovoltaic  systems  .  Journal  of Renewable and Sustainable Energy, vol. 7, no. 4, pp. 321-329, (2015).</unstructured_citation></citation><citation key="ref4"><doi>10.1016/j.jpowsour.2009.04.016</doi><unstructured_citation>Lalouni, S Rekioua, D    Rekioua, T and Matagne,  E.  ,  Fuzzy  logic  control  of stand-alone  photovoltaic  system  with battery  storage.  Journal  of  Power Sources,  vol.  193,  no.  2  pp.  899-907, (2009).</unstructured_citation></citation><citation key="ref5"><doi>10.1063/1.4928680</doi><unstructured_citation>Mohamed Farahat, A Mohamed Enany, A and  Ahmed  Nasr.  ,  Assessment  of maximum   power   point   tracking techniques  for  photovoltaic  system applications. Journal of Renewable and Sustainable  Energy,  vol.  7,  no.  4,  pp. 568-585, (2015).</unstructured_citation></citation><citation key="ref6"><doi>10.1063/1.4936572</doi><unstructured_citation>Soubhagya  Kumar  Dash, Savita  Nema, Nema,  RK   and  Deepak  Verma  , A comprehensive assessment of maximum power  point  tracking  techniques  under uniform and non-uniform irradiance and its  impact  on  photovoltaic  systems. A review.  Journal  of  Renewable  and Sustainable  Energy,  vol.  7,  no.  6,  pp. 260-272, (2015). </unstructured_citation></citation><citation key="ref7"><doi>10.1016/j.rser.2013.02.011</doi><unstructured_citation>Pallavee Bhatnagar, A and Nema, BRK. ,  Conventional  and  global  maximum power  point  tracking  techniques  in photovoltaic  applications:  A  review. Journal  of  Renewable  and  Sustainable Energy vol. 5, no. 3, pp. 689-692, (2013).</unstructured_citation></citation><citation key="ref8"><doi>10.1063/1.4906982</doi><unstructured_citation>Hadeed  Ahmed  Sher,  Ali  Murtaza,  F Abdullah  Noman,  Khaled  Addoweesh, E and   Marcello  Chiaberge  ,  An intelligent control strategy of fractional short  circuit  current  maximum  power point tracking technique for photovoltaic applications. Journal of Renewable and Sustainable  Energy,  vol.  7,  no.  1,  pp. 448-460, (2015). </unstructured_citation></citation><citation key="ref9"><doi>10.1109/supergen.2009.5348168</doi><unstructured_citation>Jiyong Li  and Honghua Wang , Maximum  Power  Point  Tracking  of Photovoltaic  Generation  Based  on  the Fuzzy    Control    Method.    IEEE international  conference  on  sustainable power  generation  and  supply,  pp.  1-6, (2009). </unstructured_citation></citation><citation key="ref10"><doi>10.1109/41.925586</doi><unstructured_citation>Yeong-Chau  Kuo,  Tsomg-Juu Liang  and  Jiann-Fuh  Chen  ,Novel Maximum   Power   Point   Tracking Controller  for  Photovoltaic  Energy Conversion System . IEEE Transactions on Industrial Electronics, vol. 48, no. 3, pp. 594-601, (2001).</unstructured_citation></citation><citation key="ref11"><doi>10.1016/j.proeng.2011.12.677</doi><unstructured_citation>Yinqing Zou , Youling Yu, Yu Zhang and Jicheng Lu , MPPT Control for PV Generation System Based on an Improved   Incremental   conductance Algorithm.  International  workshop  on Information and Electronics Engineering,  vol.  29,  pp.  105-109, (2012).</unstructured_citation></citation><citation key="ref12"><doi>10.1109/optim.2010.5510441</doi><unstructured_citation>Ahmad Al-Diab and Constantinos Sourkounis , Variable Step Size  P&amp;O  MPPT  Algorithm  for  PV Systems.  12th  International  Conference on  Optimization  of  Electrical  and Electronic   Equipment,   (OPTIM), pp. 1097-1102, (2010).</unstructured_citation></citation><citation key="ref13"><doi>10.1016/j.egypro.2011.05.062</doi><unstructured_citation>Chekired, F, Larbes, C, Rekioua, D and Haddad, F, Implementation of a MPPT fuzzy controller for photovoltaic systems  on  FPGA  circuit.  International conference on MEDGREEN, vol. 6, pp. 541-549, (2011). </unstructured_citation></citation><citation key="ref14"><doi>10.1016/j.egypro.2011.05.073</doi><unstructured_citation>Bouchafaa,  F  Hamzaoui,  I  and Hadjammar.  ,  Fuzzy  Logic  Control  for the tracking of maximum power point of a  PV  system.  International  conference MEDGREEN, Energy Procedia, vol. 6, pp. 633-642, (2011).</unstructured_citation></citation><citation key="ref15"><doi>10.5120/5594-7840</doi><unstructured_citation>Balasubramanian, G and  Singaravelu, S. , Fuzzy  logic  controller  for  the  maximum power  point  tracking  in  photovoltaic system. International Journal of Computer Applications,  vol.  41,  no.12,  pp.  22-28, (2012). </unstructured_citation></citation><citation key="ref16"><doi>10.1109/63.903988</doi><unstructured_citation>Eftichios   Koutroulis,   Kostas Kalaitzakis and Nicholas Voulgaris, C. , Development  of  a  Microcontroller-Based,  Photovoltaic  Maximum  Power Point  Tracking  Control  System.  IEEE transactions  on  power  electronics,  vol. 16, no. 1,  pp. 46-54, (2001).</unstructured_citation></citation><citation key="ref17"><unstructured_citation>Khaehintung  N,  Wiangtong  T and Sirisuk, P. , FPGA Implementation of MPPT Using Variable Step-Size P&amp;O Algorithm  for  PV  Applications.  IEEE International Symposium on Communications   and   Information technologies,  vol.  06,  pp.  212-215, (2006). </unstructured_citation></citation><citation key="ref18"><doi>10.1002/pip.950</doi><unstructured_citation>Mekki  H,  Mellit  A,  Kalogirou SA, Messai, A and Furlan, G. , FPGA-Based  implementation  of  a  real  time photovoltaic module simulator. Progress in   Photovoltaics:   Research   and Application,  vol. 18, no. 2, pp. 115-127, (2010).</unstructured_citation></citation><citation key="ref19"><doi>10.1016/j.solener.2010.12.004</doi><unstructured_citation>Messai, A. Mellit, A. Guessoum, A and Kalogirou, SA. , Maximum power point  tracking  using  a  GA  optimized fuzzy  logic  controller  and  its  FPGA implementation. Journal of Solar energy, vol. 85, no. 2,  pp. 265-277, (2011). </unstructured_citation></citation><citation key="ref20"><doi>10.1109/revet.2012.6195248</doi><unstructured_citation>Salmi,  T,  Bouzguenda,  M, Gastli,   A   and   Masmoudi,   A.   , Matlab/Simulink  based  modelling  of solar  photovoltaic  cell.  International Journal of Renewable Energy Research, vol. 2, no. 2,  pp. 213-218,(2012). </unstructured_citation></citation><citation key="ref21"><doi>10.1115/imece2014-37967</doi><unstructured_citation>Shimi   Sudha   Letha,   Tilak Thakur,  Jagdish  Kumar,  Dnyaneshwar Karanjkar  and  Santanu  Chatterji.  , Design  and  Real  Time  Simulation  of Artificial Intelligent Based MPP Tracker for   Photo-Voltaic   System.   ASME International  mechanical  engineering congress and exposition, vol. 6, no. 2,pp. 11-20, (2014). </unstructured_citation></citation><citation key="ref22"><doi>10.1115/1.4007852</doi><unstructured_citation>Averbukh, M, Ben-Galim, Y and Uhananov, A. , Development of a Quick Dynamic  Response  Maximum  Power Point  Tracking  Algorithm  for  Off-Grid System With Adaptive Switching (On–Off) Control of dc/dc Converter. Journal Solar Energy Engineering, vol. 135, no. 2,pp. 1268-1279,(2012).</unstructured_citation></citation><citation key="ref23"><unstructured_citation>Seung Hoe Choi, Jin Hee Yoon,  Fuzzy  Regression  Based  on  Non-Parametric     Methods,     WSEAS Transactions  on  Systems  and  Control,   Volume   13,   2018, pp.   20-25.</unstructured_citation></citation><citation key="ref24"><unstructured_citation>Dzenan     Gusic,     Sanela NesimovicAutomatization  in  Vague Database  Relations  via  Lukasiewicz Fuzzy  Implication  Operator,  WSEAS Transactions  on  Systems  and  Control, pp. 445-459, Volume 14, 2019.</unstructured_citation></citation></citation_list></journal_article></journal></body></doi_batch>