<doi_batch xmlns="http://www.crossref.org/schema/4.4.0" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" version="4.4.0"><head><doi_batch_id>58b4f2db-1487-420a-9c84-7d30188789d3</doi_batch_id><timestamp>20210112125228612</timestamp><depositor><depositor_name>wsea</depositor_name><email_address>mdt@crossref.org</email_address></depositor><registrant>MDT Deposit</registrant></head><body><journal><journal_metadata language="en"><full_title>WSEAS TRANSACTIONS ON POWER SYSTEMS</full_title><issn media_type="print">1790-5060</issn><doi_data><doi>10.37394/232016</doi><resource>http://wseas.org/wseas/cms.action?id=4057</resource></doi_data></journal_metadata><journal_issue><publication_date media_type="online"><month>2</month><day>17</day><year>2020</year></publication_date><publication_date media_type="print"><month>2</month><day>17</day><year>2020</year></publication_date><journal_volume><volume>15</volume><doi_data><doi>10.37394/232016.2020.15</doi><resource>http://wseas.org/wseas/cms.action?id=23192</resource></doi_data></journal_volume></journal_issue><journal_article language="en"><titles><title>Study of Fuzzy Controllers Performance: Application on Embedded Systems</title></titles><contributors><person_name sequence="first" contributor_role="author"><given_name>L. M.</given_name><surname>Muniz</surname><affiliation>CEFET-MG, Department of Eletroelectronics,  Leopoldina, BRAZIL</affiliation></person_name><person_name sequence="additional" contributor_role="author"><given_name>M. J.</given_name><surname>Carmo</surname><affiliation>CEFET-MG, Department of Eletroelectronics,  Leopoldina, BRAZIL</affiliation></person_name><person_name sequence="additional" contributor_role="author"><given_name>M. F.</given_name><surname>Santos</surname><affiliation>CEFET-MG, Department of Eletroelectronics,  Leopoldina, BRAZIL</affiliation></person_name><person_name sequence="additional" contributor_role="author"><given_name>A. F.</given_name><surname>Santos Neto</surname><affiliation>CEFET-MG, Department of Eletroelectronics,  Leopoldina, BRAZIL</affiliation></person_name><person_name sequence="additional" contributor_role="author"><given_name>P.</given_name><surname>Mercorelli</surname><affiliation>Leuphana University of Luneburg, Institute of Product and Process Innovation, Luneburg, GERMANY</affiliation></person_name></contributors><jats:abstract xmlns:jats="http://www.ncbi.nlm.nih.gov/JATS1"><jats:p>Nowadays the industrial field is testing more robust controllers to deal better with complex control processes, to guarantee high reliability and efficiency. In this context, this work aims to present the design of a Fuzzy Controller embedded in an Arduino Mega microcontroller, taking 2 experimental didactic plants into consideration: a resistor-capacitor circuit and a direct current motor assembly. Then, the Fuzzy Controller will have its effectiveness and also be compared with other topology: the parallel PID controller. In addition, an interesting study is done when the storage capacity of routines in the Arduino board is considered, regarding the dynamic memory when new membership functions and rules are increased. The Fuzzy controller was embedded obtaining satisfactory results when compared to the PID controller, taking non-intrusive performance indices as validation parameters.</jats:p></jats:abstract><publication_date media_type="online"><month>5</month><day>11</day><year>2020</year></publication_date><publication_date media_type="print"><month>5</month><day>11</day><year>2020</year></publication_date><pages><first_page>87</first_page><last_page>93</last_page></pages><ai:program xmlns:ai="http://www.crossref.org/AccessIndicators.xsd" name="AccessIndicators"><ai:free_to_read start_date="2020-05-11"/><ai:license_ref applies_to="am" start_date="2020-05-11">https://www.wseas.org/multimedia/journals/power/2020/a205116-079.pdf</ai:license_ref></ai:program><archive_locations><archive name="Portico"/></archive_locations><doi_data><doi>10.37394/232016.2020.15.10</doi><resource>http://www.wseas.org/multimedia/journals/power/2020/a205116-079.pdf</resource></doi_data><citation_list><citation key="ref0"><doi>10.1016/j.jprocont.2015.11.002</doi><unstructured_citation>M.  Bauer,  A.  Horch,  L.  Xie,  M.  Jelali,  andN. Thornhill, “The current state of control loopperformance monitoring–a survey of applicationin industry,”Journal of Process Control, vol. 38,pp. 1–10, 2016.</unstructured_citation></citation><citation key="ref1"><unstructured_citation>B.  Bouchon-Meunier,  “La  logique  floue  et  sesapplications.” 1995.</unstructured_citation></citation><citation key="ref2"><unstructured_citation>M. G. Simoes and I. S. Shaw, “Controle e mod-elagem  fuzzy,”Editor Blucher: FAPESP, S ̃aoPaulo, 2007.</unstructured_citation></citation><citation key="ref3"><unstructured_citation>L. Mastacan and C. Dosoftei, “Fuzzy logic con-troller design and implementation for industrialapplications,” 2014.</unstructured_citation></citation><citation key="ref4"><unstructured_citation>A. Singh and P. S. Londhe,  “Design of signeddistance method based fuzzy logic controller fortito,” 2017.</unstructured_citation></citation><citation key="ref5"><unstructured_citation>B. V. Murthy, Y. V. P. Kumar, and U. V. R. Ku-mari,  “Fuzzy  logic  intelligent  controlling  concepts  in  industrial  furnace  temperature  process control,” 2012.</unstructured_citation></citation><citation key="ref6"><doi>10.1109/ccsse.2016.7784388</doi><unstructured_citation>N. U. Ahamed, Z. B. Taha, I. B. M. Khairuddin,M. F. Rabbi, S. A. M. M. Rahaman, and K. Sun-daraj, “Fuzzy logic controller design for intelligent air-conditioning system,” 2016.</unstructured_citation></citation><citation key="ref7"><unstructured_citation>S.-T. Lin and A.-K. Huang, “Hierarchical fuzzy force control for industrial robots,”IEEE Transactions on Industrial Electronics, 1998.</unstructured_citation></citation><citation key="ref8"><doi>10.3182/20130828-3-uk-2039.00003</doi><unstructured_citation>J.  Sobota,  R.  PiˆSl,  P.  Balda,  and  M.  Schlegel, “Raspberry pi and arduino boards in control education,” IFAC Proceedings Volumes,  vol.  46,no. 17, pp. 7–12, 2013.</unstructured_citation></citation><citation key="ref9"><unstructured_citation>L. A. Zadeh, “Fuzzy sets,”Information and control, vol. 8, no. 3, pp. 338–353, 1965.</unstructured_citation></citation><citation key="ref10"><unstructured_citation>K. J.Astrom and T. Hagglund, PID controllers:theory, design, and tuning.Instrument society of America Research Triangle Park, NC, 1995,vol. 2.</unstructured_citation></citation><citation key="ref11"><unstructured_citation>C. L. Smith, “Digital computer process control,” Scranton, PA, EUA, International Textbook Co,1972.</unstructured_citation></citation><citation key="ref12"><unstructured_citation>J. G. Ziegler and N. B. Nichols, “Optimum set-tings for automatic controllers,”Transaction of ASME, vol. 64, no. 11, 1942.</unstructured_citation></citation><citation key="ref13"><unstructured_citation>K. L. Chien, “On the automatic control of gen-eralized passive systems,” Trans. Asme, vol. 74,pp. 175–185, 1972.</unstructured_citation></citation><citation key="ref14"><doi>10.1021/i200032a041</doi><unstructured_citation>D. E. Rivera, M. Morari, and S. Skogestad, “Internal model control: PID controller design,”Industrial &amp; engineering chemistry process design and development,  vol.  25,  no.  1,  pp.  252–265,1986.</unstructured_citation></citation></citation_list></journal_article></journal></body></doi_batch>