<doi_batch xmlns="http://www.crossref.org/schema/4.4.0" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" version="4.4.0"><head><doi_batch_id>a18deb7d-92f1-4fca-8a95-479b0186c461</doi_batch_id><timestamp>20210112121059953</timestamp><depositor><depositor_name>wsea</depositor_name><email_address>mdt@crossref.org</email_address></depositor><registrant>MDT Deposit</registrant></head><body><journal><journal_metadata language="en"><full_title>WSEAS TRANSACTIONS ON POWER SYSTEMS</full_title><issn media_type="print">1790-5060</issn><doi_data><doi>10.37394/232016</doi><resource>http://wseas.org/wseas/cms.action?id=4057</resource></doi_data></journal_metadata><journal_issue><publication_date media_type="online"><month>2</month><day>17</day><year>2020</year></publication_date><publication_date media_type="print"><month>2</month><day>17</day><year>2020</year></publication_date><journal_volume><volume>15</volume><doi_data><doi>10.37394/232016.2020.15</doi><resource>http://wseas.org/wseas/cms.action?id=23192</resource></doi_data></journal_volume></journal_issue><journal_article language="en"><titles><title>The Improvement of Weighted Least Square State Estimation Accuracy
Using Optimal PMU Placement</title></titles><contributors><person_name sequence="first" contributor_role="author"><given_name>Khaled</given_name><surname>Al-Maitah</surname><affiliation>Department of Electrical Engineering, Faculty of Engineering,  Mutah University, Karak, Jordan</affiliation></person_name><person_name sequence="additional" contributor_role="author"><given_name>Batool</given_name><surname>Al-Khriesar</surname><affiliation>Department of Electrical Engineering, Faculty of Engineering,  Mutah University, Karak, Jordan</affiliation></person_name><person_name sequence="additional" contributor_role="author"><given_name>Abdullah</given_name><surname>Al-Odienat</surname><affiliation>Department of Electrical Engineering, Faculty of Engineering,  Mutah University, Karak, Jordan</affiliation></person_name></contributors><jats:abstract xmlns:jats="http://www.ncbi.nlm.nih.gov/JATS1"><jats:p>This paper proposed a new technique to improve the state estimation performance by optimal placement of phasor measurement units (OPP), the proposed technique is based on Simulating Annealing (SA) algorithm for OPP by comparing between the SA solution sets and choosing the optimal location of PMUs to enhance the state estimation performance. The proposed technique has been tested through IEEE 24 bus test system using power system analysis toolbox in MATLAB program. In this paper the root mean squared deviation (RMSD) has been used to determine the state estimation performance, the simulation result demonstrates that the proposed method proved its effectiveness to be one of the best methods used to improve the state estimation performance</jats:p></jats:abstract><publication_date media_type="online"><month>2</month><day>17</day><year>2020</year></publication_date><publication_date media_type="print"><month>2</month><day>17</day><year>2020</year></publication_date><pages><first_page>1</first_page><last_page>7</last_page></pages><ai:program xmlns:ai="http://www.crossref.org/AccessIndicators.xsd" name="AccessIndicators"><ai:free_to_read start_date="2020-02-17"/><ai:license_ref applies_to="am" start_date="2020-02-17">https://www.wseas.org/multimedia/journals/power/2020/a025116-655.pdf</ai:license_ref></ai:program><archive_locations><archive name="Portico"/></archive_locations><doi_data><doi>10.37394/232016.2020.15.1</doi><resource>http://www.wseas.org/multimedia/journals/power/2020/a025116-655.pdf</resource></doi_data><citation_list><citation key="ref0"><unstructured_citation>M.  Hurtgen,  J.  C.  Maun,  Advantages  of  power system  state  estimation using Phasor Measurement Units,  in Proceedings  of  the  16th  Power  Systems Computation     Conference     (PSCC),     Glasgow, Scotland, UK, 14–18 July 2008, Curran Associates: Red Hook, NY, USA, 2010, pp. 1161–1167.</unstructured_citation></citation><citation key="ref1"><doi>10.1109/67.207465</doi><unstructured_citation>A.  G.  Phadke,  Synchronized  phasor  measurements in power systems, IEEE Comput. Appl. Power, vol. 6, no. 2, pp. 10–15, Apr. 1993.</unstructured_citation></citation><citation key="ref2"><doi>10.1109/isap.2011.6082183</doi><unstructured_citation>N. M. Manousakis, G. N. Korres, P. S. Georgilakis, Optimal placement of phasor measurement units: A literature   review,   in Proceedings   of   the   16th International   Conference   on   Intelligent   System Applications to Power Systems (ISAP), Hersonissos,    Greece,    25–28    September    2011; IEEE: Piscataway, NJ, USA, 2011; pp. 1–6.</unstructured_citation></citation><citation key="ref3"><doi>10.1109/icpec.2013.6527654</doi><unstructured_citation>K.  K.  More,;  H.  T.  Jadhav,  A  literature  review  on optimal placement of phasor measurement units, in Proceedings  of  the  International  Conference  on Power,  Energy  and  Control  (ICPEC),  Dindigul, India,  6–8  February  2013;  IEEE:  Piscataway,  NJ, USA, 2013; pp. 220–224.</unstructured_citation></citation><citation key="ref4"><doi>10.1016/j.rser.2015.04.152</doi><unstructured_citation>M. Nazari-Heris, B. Mohammadi-Ivatloo, Application   of   heuristic   algorithms   to   optimal PMU  placement  in  electric  power  systems:  An updated review, Renew. Sustain. Energy Rev. 2015, pp. 214–228.</unstructured_citation></citation><citation key="ref5"><doi>10.1007/s40866-016-0009-y</doi><unstructured_citation>K.   Negash,   B.   Khan,;   E.   Yohannes,   Artificial Intelligence   Versus   Conventional   Mathematical Techniques:  A  Review  for  Optimal  Placement  of Phasor  Measurement  Units, Technol.  Econ.  Smart Grids Sustain. Energy 2016, 1, 10.</unstructured_citation></citation><citation key="ref6"><doi>10.1109/access.2015.2389659</doi><unstructured_citation>F.   Aminifar,   M.   Fotuhi-Firuzabad,   A.Safdarian, Davoudi,   A.;   M.   Shahidehpour,   Synchrophasor Measurement    Technology    in    Power    Systems: Panorama and State-of-the-Art, IEEE Access 2014, 2, pp. 1607–1628.</unstructured_citation></citation><citation key="ref7"><unstructured_citation>A.  G.  Phadke,  J.  S.  Thorp, Synchronized  Phasor Measurements  and  Their  Applications,  2010.</unstructured_citation></citation><citation key="ref8"><unstructured_citation>A.  Abur,   A.  G.  Exposito, Power   System   State Estimation:   Theory   and   Implementation,   New York, 2004.</unstructured_citation></citation><citation key="ref9"><doi>10.1109/pes.2009.5275241</doi><unstructured_citation>K. Zhu, L. Nordstrom, L. Ekstam, Application and analysis of optimum PMU placement methods with application   to   state   estimation   accuracy, IEEE Power  Energy  Society  General  Meeting,  2009.  pp. 1-7.</unstructured_citation></citation><citation key="ref10"><doi>10.1109/tpwrs.2006.881149</doi><unstructured_citation>J.  Chen  and  A.  Abur,  Placement  of  PMUs  to enable bad data detection in state estimation, IEEE Trans. Power Systems, vol. 21, no. 4, , Nov. 2006, pp. 1608–1615.</unstructured_citation></citation><citation key="ref11"><doi>10.4172/2325-9833.1000104</doi><unstructured_citation>J.  Chen,  Y.  Liao,  Optimal  Placement  of  Phasor Measurement  Units  for  Improving  Power  System State  Estimation  Accuracy:  A  Heuristic  Approach, J. Electr. Eng. Electron. Technol. 2012, 1.</unstructured_citation></citation><citation key="ref12"><doi>10.3390/en11030570</doi><unstructured_citation>M.     Shahriar,     I.     Habiballah,     H.     Hussein, Optimization  of  Phasor  Measurement  Unit  (PMU) Placement    in    Supervisory    Control    and    Data Acquisition   (SCADA)-Based   Power   System   for Better    State-Estimation    Performance, Energies 2018, 11, 570, 10.3390/en11030570.</unstructured_citation></citation></citation_list></journal_article></journal></body></doi_batch>