WSEAS Transactions on Power Systems


Print ISSN: 1790-5060
E-ISSN: 2224-350X

Volume 12, 2017

Notice: As of 2014 and for the forthcoming years, the publication frequency/periodicity of WSEAS Journals is adapted to the 'continuously updated' model. What this means is that instead of being separated into issues, new papers will be added on a continuous basis, allowing a more regular flow and shorter publication times. The papers will appear in reverse order, therefore the most recent one will be on top.



Impact of Static and Dynamic Load Model on the Low Voltage Ride-Through of the Doubly-Fed Induction Generator Wind Farm

AUTHORS: Abdelaziz Salah Saidi, Mohammed Ibrahim Y. Al-Rayif

Download as PDF

ABSTRACT: The increasing penetration of load model in distribution systems may significantly affect voltage stability of the systems, particularly during Low Voltage Ride-Through (LVRT) wind turbine. The main objective of this work is to present the impact of different static and dynamic load models, on the LVRT recovery after disturbances. A component and composite loading structures are considered, comprising static, dynamic motor and a composite model. Motor loads are assessed with respect to their mechanical loads. The polynomial load model using load class and load type is investigated thoroughly under various operating conditions. The present paper examines the effect of nonlinear loads as well as different mechanical torque and inertia of induction motor loads on the transient stability and observing the fault recovery performance of the Doubly-Fed Induction Generator (DFIG) wind turbine system. The dynamic impacts between wind turbines (WTs) and motor loads are also examined. The complete system is modeled and simulated using PSAT/MATLAB software environment in such a way that it can be suited for modeling of all types of loads configurations. The LVRT capability is investigated and the results of voltage dip ride-through simulations are presented for both static and dynamic load.

KEYWORDS: Low Voltage Ride-Through, doubly-fed induction generator wind turbine, static load, dynamic load, composite load modeling, transient stability

REFERENCES:

[1] Francisco K. A. Lima, Alvaro Luna, Pedro Rodriguez, Edson H. Watanabe, and Frede Blaabjerg, Rotor Voltage Dynamics in the Doubly-Fed Induction Generator During Grid Faults, IEEE Transactions on Power Electronics, Vol. 25, No. 1, January 2010.

[2] J. Morren, S.W.H. de Haan, Ride through of wind turbines with doubly-fed induction generator during a voltage dip, IEEE Transaction on Energy Conversion, vol. 20, no. 2, June 2005, pp. 435 – 441.

[3] A.D. Hansen, G. Michalke, P. Sørensen, T. Lund, F. Iov, Coordinated voltage control of DFIG wind turbines in uninterrupted operation during grid faults, Wind Energy, No. 10, 2007, pp. 51-68.

[4] Marwa Ezzat, Mohamed Benbouzid, Sm Muyeen, Lennart Harnefors. Low-Voltage Ride-Through Techniques for DFIG-Based Wind Turbines: State-ofthe-Art Review and Future Trends, IEEE IECON, Nov 2013, Vienne, Austria. pp. 7681-7686.

[5] F. Iov, A. D. Hansen, P. Sørensen and N. A. Cutululis, Mapping of grid faults and grid codes, Tech. Rep. Risø-R-1617(EN), Risø Nat. Lab., Tech. Univ. Denmark, Roskilde, Denmark, Jul. 2007.

[6] J. Kabouris and F. D. Kanellos, Impacts of Large Scale Wind Penetration on Energy Supply Industry, Energies 2009, available: http://www.mdpi. com/1996-1073/2/4/1031.

[7] E. ON Netz GmbH, Bayreuth, Requirements for Offshore Grid Connections in the E. ON Netz Network, Updated: 2008, Available: http://www.eonnetz.com.

[8] K.Gunalan and C.Sharmeela, A New Control strategy to Enhance LVRT for Doubly Fed Induction Generator, WSEAS TRANSACTIONS on POWER SYSTEMS, Volume 10, 2015. Motor 1 TL,1=0.3 (p.u.) Motor 2 TL,2 = 0.07+ 0.16ω+ 0.07 ω2 (p.u.) Motor 3 TL,3 = 0.05+ 0.08 ω+ 0.18 ω2 (p.u.) From Bus To Bus Nom. V (kV) R (p.u.) X (p.u.) 5 2 30 0.023 0.2 2 3 30 0 0.01 4 3 30 0.2 0.05 2 6 30 0 0.3 1 6 30 0.023 0.1 6 7 30 0 0.2 6 7 30 0 0.2 7 8 30 0 0.1 Bus 8 Slack generator Voltage 1.00 p.u Bus 1 PV controlled Voltage 1.00 p.u P=100 MW Bus 5 PV controlled Voltage 1.00 p.u P=50 MW Table. 4. Transmission Line Parameters (values at 100 MVA base) Table. 2. Generator Data Table. 5. Mechanical Load Data

[9] H.T. Jadhav and R. Roy, A comprehensive review on the grid integration of doubly fed induction generator, International Journal of Electrical Power & Energy Systems, vol. 49, July 2013, pp. 8-18.

[10] Min Min Kyaw, V. K. Ramachandaramurthy and Dao Trung Hieu, Fault Ride through of Offshore Wind Turbines with Optimum Power Tracking, PEA-AIT International Conference on Energy and Sustainable Development: Issues and Strategies (ESD 2010) The Empress Hotel, Chiang Mai, Thailand. 2-4 June 2010.

[11] Leszek Jedut, Eugeniusz Rosolowski and Krzysztof Rudion, Investigation of DFIG Based Wind Turbine Influence on the Utility Grid, Modern Electric Power Systems 2010, Wroclaw, Poland. MEPS'10 - paper 05.5.

[12] N. K. Roy, M. J. Hossain, and H. R. Pota, Voltage profile improvement for distributed wind generation using D-STATCOM, in Proc. IEEE Power and Energy Society General Meeting, Detroit, USA, 24-28 July 2011.

[13] Ching-Yin Lee, Li-Chieh Chen, Shao-Hong Tsai, Wen-Tsan Liu, and Yuan-Kang Wu, The impact of SCIG wind farm connecting into a distribution system, in Proc. Asia-Pacific Power and Energy Engineering Conference (APPEEC 2009), pp. 1-7, China.

[14] D.J. Hill, Nonlinear dynamic load models with recovery for voltage stability studies, IEEE Trans. Power Sys., Vol.8, No.1, Feb. 1993.

[15] N. K. Roy, H. R. Pota, and M. J. Hossain, Reactive power management of distribution networks with wind generation for improving voltage stability, Renewable Energy-Elsevier, vol. 58, 2013, pp. 84-95.

[16] Western Electricity Coordinating Council Modeling and Validation Work Group, Composite Load Model for Dynamic Simulations, Report 1.0, June 12, 2012.

[17] Milano, F., Power System Analysis Toolbox Documentation for PSAT, Version 1.3.4. July 14, 2005.Available: http://www.power.uwaterloo.ca/~fmilano/psat.htm

[18] Ghedamsi, K. and D. Aouzellag, Improvement of the performances for wind energy conversions systems. Int. J. Electronic Power Energy Syst., 2010.

[19] Ekanayake, J.B., L. Holdsworth and N. Jenkins, Comparison of 5th order and 3rd order machine models for doubly fed induction generator (DFIG) wind turbines, Electr. Power Syst. Res. 67,2003, pp. 207–215.

[20] Tsourakis, G., B.M. Nomikos and C.D. Vournas, Effect of wind parks with doubly fed asynchronous generators on small-signal stability, Electric Power Syst. Res., 79, 2009, pp. 190–200.

[21] Milano, F., Assessing adequate voltage stability analysis tools for networks with high wind power penetration, Proceedings of the 3rd International Conference on Electric Utility Deregulation and Restructuring and Power Technologies, April 6-9, Nanjing, China, 2008, pp. 2492-2497.

[22] Milano, F., A.J. Conejo and J.L. Garcia-Domelas, Reactive power adequacy in distribution networks with embedded distributed energy resources, J. Energy Eng. 133, 2007, pp. 132-143.

[23] P.Kundur, Power System Stability and Control, McGraw-Hill Inc., 1994.

[24] C. W. Taylor, N. J. Balu, and D. Maratukulam, Power system voltage stability, New York: McGraw Hill, 1994.

[25] T. Van Cutsem and C. Vournas, Voltage Stability of Electric Power Systems, Kluwer, 1998.

[26] J. Hossain and H. R. Pota, Robust Control for Grid Voltage Stability: High Penetration of Renewable Energy, Springer Singapore, 2014.

[27] IEEE Task Force on Load Representation for Dynamic Performance, Standard load models for power flow and dynamic performance simulation, IEEE Trans. Power Syst., vol.10, no. 3, August 1995, pp. 1302-1313

[28] A. Borghetti, R. Caldon, A. Mari and C. A. Nucci, Studies, IEEE Transactions on Power Systems, Vol. 12, No. 1, February 1997.

[29] Junji Tamura, Masahiro Ueno and Yoshiharu Matsumura, Transient stability simulation of power system including wind generator by PSCAD/EMTDC, IEEE Porto Power Tech Conference, 10-13 Septenber 2001, Porto, Portugal.

[30] Mark Gordon, Impact of Load Behavior on Transient Stability and Power Transfer Limitations, IEEE Power and Energy Society General Meeting. July 26-30, 2009.

[31] Usaola, J.L., P. Rodriguez, J.M. Fernandez, J.L. Beato, D. Iturbe and Jr. R. Wilhelmi, Transient stability studies in grids with great wind power penetration, Modelling issues and operation requirements, Power Eng. Soc. General Meeting, 2003, pp. 1534-1541.

[32] G. Durga Prasad and Mubarak A.Al-Mulhim, Comparative assessment of the effect of the dynamic load models on voltage stability, Electrical Power § Energy Systems, Vol. 19, No. 5, 1997, pp. 305-309.

WSEAS Transactions on Power Systems, ISSN / E-ISSN: 1790-5060 / 2224-350X, Volume 12, 2017, Art. #1, pp. 1-10


Copyright © 2017 Author(s) retain the copyright of this article. This article is published under the terms of the Creative Commons Attribution License 4.0

Bulletin Board

Currently:

The editorial board is accepting papers.


WSEAS Main Site